Pulsar Pro Manual

Pulsar Pro – Online Installation Guide

1. Technical Specifications

General Specifications

Charging Mode (IEC 61851-1) Mode 3
Dimensions without cable 198x201x99 mm (without cable)
Weight without cable 1.3 kg (without cable)
Operating Temperature -30 ºC to 50 ºC
Storage Temperature -40 ºC to 70 ºC
Environmental Ratings IP55, IK10 (High resistance)
Installation Place Indoor and outdoor use
Mounting Type Fixed equipment fastened to the wall. Floor-standing installation with appropriate Wallbox accessories.
Intended for Use Equipment intended for use by ordinary persons.
Location of Access Equipment for both unrestricted and restricted access locations.
Standards CE, UKCA, EAC, and RCM mark. IEC 61851-1, IEC 61851-21-2, IEC 62196, BS 7671, IEC 60364. RED Directive 2014/53/EU and RoHS Directive 2011/65/EU
*Complies with UK Smart Charging Regulations

Electrical Specifications

Charging Power 7.4 kW (1P) 11 kW (3P)* 22 kW (3P)
Rated Voltage AC ± 10% 230 V 400 V 400 V
Rated Current 32A 16A 32A
*22kW charger limited to 11kW during installation

 

Configurable Current From 6A to rated current
Rated Frequency 50 Hz / 60 Hz
Rated Diversity Factor (RDF) 1
Rated Insulation Voltage 400 V
Rated Diversity Factor CAT III
Rated Impulse Withstand Voltage 4000 V
Overvoltage Category DC 6mA
RCCB Type A, B or EV may be required according to regional regulations
Protection Against Electric Shock Class I
Cable Section Up to 13 mm²
Connection of Power Supply Equipment EV AEVCS permanently connected to the AC grid
Pollution Degree PD3
Electromagnetic Environment Class A + Class B

2. Safety Warnings

Veiligheidswaarschuwingspictogrammen
  • Flying debris, risk of eye injury
  • Risk of electric shock.
    Disconnect and wait 10 minutes.
  • Caution
  • Sharp element, risk of cuts
  • Earthing connection required
  • Special waste disposal

3. Tools and Mounting Parts

Required Tools

gereedschap & montageonderdelen
  • Hammer
  • Step drill 32mm and drill bit 8mm
  • Pencil
  • Flat screwdriver
  • Phillips screwdriver
  • Cutting pliers
  • Torx T20 and T15
  • Measuring tape
  • Utility knife
  • Spirit level

Included Mounting Parts

  • Phillips screws ø6 x 50 mm
  • Phillips screws ø5 x 40 mm
  • Wall anchors ø8 x 40 mm
  • M32 gland
  • Torx screws T20 4 x 10 mm
  • Torx screws T15 ø3.5 x 8 mm

4. Preparing the Charger

Remove the two corner screws and carefully lift the cover. Then, gently disconnect the ribbon cable and set the cover aside.

Switch off all connections before proceeding with the installation.

5. Installing the Wall Plate

Remove the tape from the wall plate to detach it from the charger. Then, level it and mark three holes with a pencil. Now, drill with a drill bit of the appropriate size and align the wall plate with the holes.

If you are attaching your charger to a solid wall, use the wall anchors provided with your charger.

Mount the wall plate to the wall, being careful not to overtighten the screws.

If the power supply wiring comes from the wall, you must thread the wires through the hole in the wall plate before attaching the wall plate.

6. Lower Connection

Both lower and rear connections are possible when installing Pulsar Pro. If you wish to install the product using the lower hole, please follow the instructions below. For rear connection, please proceed to chapter 7.

Lift your charger and hang it from the top of the wall plate. Fasten the charger to the wall plate using the appropriate screws, being careful not to overtighten them.

Make an incision in the gland and feed the power supply cable.

7. Rear Connection

Make a hole in the back of the charger with a 32mm Step drill. Then, make an incision in the gland and feed the power supply cable.

Fasten your charger to the wall plate and secure it with the appropriate screws.

Go to the EMS Installation Guide to discover which functionalities are supported by Pulsar Pro.

8. Electrical Wiring

Single-Phase Version

  • Single-Phase Setup
  • Bi-phase No neutral
  • Single-Phase PME

(UK only) Can be connected to the PME supply in accordance with BS7671:2018-amd1:2020 722.411.4.1

Three-phase Version

D. Three-phase setup

E. Three-phase no neutral

F. Bi-phase setup

For three-phase No Neutral installation check compatible EV models supporting this configuration.

The Pulsar Pro three-phase version can be installed with A – B setups.

Make sure the maximum voltage between L & N inputs is lower than 264V.

9. Closing the charger

Set the power selector switch to an appropriate setting. Then carefully reattach the communication cable to the charger’s cover and close it.

Make sure the selector is not on 0, 8 or 9. 

Place the four corner screws to secure the charger’s cover. Make sure to properly align the bottom screw opening, place the decorative frame on your charger and secure the frame with the screw. Do not overtighten.

10. Installing the plug holder

Place the plug holder on the wall and mark the fixing points. Then drill holes where the fixing points are marked.

Insert the anchor screws into the fixing holes. Then fix the device to the walls by inserting and tightening the screws.

11. Registering the charger

Download the Wallbox app and register.